CAN OPEN

CABLE Li02Y(St)C11Y CanBUS - sect. 2x2x0.34mm² - Braid Shield – PUR jacket O.D. 6.70mm - AWM Style 20236 (80°C / 30V)

CODE : 86A22T1401-E30

Homologation UL AWM style: 20236

Accordance to Directives: 2014/35/UE; 2014/30/UE;                                         2011/65/CE; 2015/863/UE

                                       CAN BUS Accordance to: ISO 11898-2

GENERAL CONSTRUCTION

2x2x0.34mm²
Conductor

Stranded Bare copper wire; 42x0.10mm (nom. 0.34mm² - AWG22); nominal diameter 0.80mm; cl.6 VDE0295;
Lay agree with UL 758 tab 5.9; Conform to EN 13602 - ETP1, DIN 40500 E-Cu 58.

Insulation

Foam PE (with internal and external skin); hardness 61 ShD; diameter 1.75 ±0.10mm; Colours cores: White-Brown-Green-Yellow as for DIN47100.

Assembly

Four cores stranded in star quad (see indicative sketch); some filler could be used for a better roundness.

Shield

First: Al/PET tape wrapped over total assembly (Aluminium face outside); Optical coverage 100%.
Second: Braid type; Tin copper wire 0.10mm; nominal optical coverage 80%.
Drain wire: Stranded Tin copper wire 0.25mm² (AWG24); DW under braid shield.

Protective tape:

PET tape wrapped over assembly.

Protective tape:

Nonwovens tape (TNT) over total shield.

Jacket:

PUR, hardness 92 ShA; diameter 6.70 ±0.20mm; colour Violet similar RAL4001; conform to UL 20236.

TECHNICAL DATA

Electrical

Operating voltage 30V
Voltage test 1000 V x 1min
Max conductor resistance 61.6 Ω/Km
Impedance 120 Ω ± 10%
Nominal Capacitance @1KHz: 50 pF/m

Chemical

Oil resistance yes (UL758; ISO6722)
Free of FCKW, Silicone and Pb - yes
Halogen free - yes (CEI EN 60754-1 / VDE 0482-754-1)

Physical

UV resistant yes (UL1581– 300h)
Max installation pulling force 50N

Physical

Operating temperature range -40°C to +80°C (fixed)
Operating temperature range -30°C to +80°C (free motion without periodic recurrence and forced guidance)
Bending radius >10 x OD (fixed)
Bending radius >15 x OD (Flex and drag chain)
UV resistant yes (UL1581/2556– 300h)

Flame

Flame resistant
UL Cable Flame test; CSA FT1; IEC 60332-1; ISO6722

Movement data @20°C:

Acceleration: up to 20 m/sec²
Speed: up to 300 m/min
Torsion: ±30° (Optimal recommended)

Default criterium of the norm-bendings is electrical failure due to conductor breakage or conductor short-circuit. Extreme sheath adhesion is not a default criterium since it cannot be influenced by the cable manufacturer (e.g. through big abrasion between cable and chain, non-suitable chain construction or wrong installation of cable in the chain).

Cavi BUS e DATI questa tipologia di cavi viene utilizzata per gestire la trasmissione dati per sistemi complessi dove si richiedono valori di impedenza e velocità di trasmissione. Sono disponibili due gamme di prodotti per posa dinamica o posa statica, in rispondenza alle omologazioni UL, CSA e DESINA. 