Industrial Ethernet Cable Cat.7 – Sect. 4x(2xAWG24/7) - PUR jacket - AWM Style 20236 (80°C / 30V)
CODE : 86A24SS8C7-004
Homologation UL AWM style: 20233
Accordance to Directives: 2014/35/UE; 2011/65/CE; 015/863/UE
Accordance to Directives: Electrical Equipment (Safety) Regulations 2016
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012.
GENERAL CONSTRUCTION
Conductor
Stranded bare copper wire 0.20mm; nom. section 0.22mm²- AWG24; nominal diameter 0.6mm.
Lay agree with UL 758 tab 5.9; conform to EN 13602 - ETP1, DIN 40500 E-Cu 58.
Insulation
Foam Polyolefin compound; nominal diameter 1.4mm; colours Orange - White polarized Orange - Green – White polarized Green - Brown - White polarized Brown - Blue - White polarized Blue.
Pairs assembly
Cores twisted in pairs; Pairs colours (Orange - White pol. Orange) - (Green - White polarized Green) – (Brown - White pol. Brown) - (Blue - White pol. Blue).
Pairs shield
Each pair shielded with Al/PET tape (Aluminium face outside); optical coverage 100%.
Total assembly
Pairs 4x(2xAWG24) stranded together around a CW (see indicative Sketch).
Total shield
Braid type; Tin copper wire; nominal optical Coverage 80%.
Protective tape:
Tape under and over shield.
Jacket:
PUR compound; diameter 9.4 ±0.25mm; Colour Green similar RAL6026; conform to UL AWM Style 20233
TECHNICAL DATA
Electric
Operating voltage 300 Vrms
Voltage test 700 Vac
Peak Operating Voltage 125Vdc (not for high voltage purposes)
Cable suitable for installation in coexistence with Category I energy cables with voltage rating up to 0,6/1 KV according to CEI-UNEL 36762.
Physical
Operating temperature range -40°C to +80°C (fixed)
Operating temperature range --25°C to +80°C (flex)
Minimum bending radius 7.5 x D (fixed)
Minimum bending radius 12.5 x D (flex)
Max installation pulling force 100N
UV resistant yes (UL1581-300h)
Chemical
Oil resistance - yes (UL758;
Silicone, Pb, Cd, Hg, FCKW free - yes
Halogen free - yes (CEI EN 60754-1 / VDE 0482-754-1)
Electrical transmission properties @20°C:
Max electric resistance - 95.3 Ω/Km (IEC 60344)
Impedance - 100 Ω ±15%
Capacitance @1KHz - 47 pF/m (nominal)
Propagation velocity - 80 % (nominal)
Propagation delay - <534 ns/100m
Delay skew - <45 ns/100m
Transfer Impedance - 5 mΩ/m @10MHz
Flame
UL Cable flame test; UL VW-1; CSA FT1; IEC 60332-1-2
Accordance to:
IEC 61156-6 - Work area wiring Cat.7
ISO11801-2 §9.3.2.6 - Flexible cable Class F
BUS and DATA cables this type of cable is used to manage data transmission for complex systems where impedance values and transmission speed are required. Two ranges of products are available for dynamic installation or static installation, in compliance with UL, CSA and DESINA approvals.