• November 24, 2024
  • Via Mappano 30/G-H 10071 Borgaro Torinese

PROFINET TYPE C

Network cable ProfiNET Type C - 2x2xAWG22 - inner jacket - Shield - PUR jacket O.D. 6.80mm

CODE : 86A22SS40D-004

Homologation UL AWM style: 20233

Accordance to Directives: 2014/35/UE; 2014/30/UE;                                         2011/65/CE; 2015/863/UE

GENERAL CONSTRUCTION

Conductor

Tinned copper strand; according to EN 13602 - ETP1; stranding according to DIN VDE 0295, EN60228 Class 6 Stranded lay compliant with UL 758.

Wire structure:

Nominal section
(mm²)
AWG Stranding
(nbr of wires x wire diameter in mm)
Diameter of stranded core
(mm)
Max Resistance
Ref. std. IEC 60344
(Ω/km)
0.34 22 19x0.15 0.75 64.2

Insulation

Thermoplastic PE; Max Insulation resistance >200 MΩxkm (IEC60189-1&IEC60885-1 or EN50289-1-4); nominal hardness 61 Shore D; according to UL758, cores colors Yellow-Blue-Orange-White.

Insulation diameter

Nominal section
(mm²)
Nominal Ø
(mm)
Nominal thickness
(mm)
0.34 1.45 19x0.15

Assembly

Cores stranded together (central filler could be used)

Inner jacket

Flame retardant compound. Nominal diameter 4.30mm, colors natural.

Duble Shield

Tape: Al/PET tape (Aluminum face outside), nominal optical coverage 100%.
Braid: Tin copper wire, nominal optical coverage 80%.

Tape:

PET tape over braid shield.

Jacket:

Polyurethane (PUR, TPU), ether base, Halogen free, nominal hardness 92 Shore A; Silicone, Pb,Cd,Hg & FCKW free; according to UL758. Diameter 6.80 ±0.20mm, colour Green similar RAL6018

*The given values have been tested individually

TECHNICAL DATA

Electrical

Voltage rating 300 V
Voltage test on core 1500 Vrms x 1 min. (EN50395)

Temperature

Temperature range (fixed) -40°C to +80°C
Temperature range (flex) -20°C to +70°C (free motion without periodic recurrence and forced guidance)

Chemical

Oil resistance yes (UL758)
Free of FCKW, Silicone and Pb yes
Halogen free yes (CEI EN 60754-1 / VDE 0482-754-1)

Physical

UV resistant yes (UL1581– 300h)
Max installation pulling force 50N

Movement data @20°C:

Minimum bending radius* 7.5 x D (up to 3 Mio Bending cycles / 6 Mio Stroke) Minimum
Minimum bending radius* 12.5 x D (up to 10 Mio Bending cycles / 20 Mio Stroke) Minimum
Max speed* 300 m/min
Max acceleration* 50 m/sec²
Torsion ± 30°/m (Max cycles 2Mio)

Flame

UL Cable Flame Test pass
UL VW-1, CSA FT1 pass
IEC 60332-1 pass
IEC 60332-2 pass

Compliance

Accordance to:
▪ 2014/35/UE; 2014/30/UE; 2011/65/CE (RoHS)
▪ ProfiNET cabling and interconnection technology Guideline for ProfiNET (3.1 March 2014)
▪ Cat.5e flex patch cord ▪ UL/CSA (UL AWM Style 20233, use: external interconnect. of electronic equipment)

BUS and DATA cables this type of cable is used to manage data transmission for complex systems where impedance values and transmission speed are required. Two ranges of products are available for dynamic installation or static installation, in compliance with UL, CSA and DESINA approvals.

Do you want to receive the technical specifications?

Fill out the form below

Contact Form inglese specifiche tecniche