Cable DEVICE-NET/CANOPEN 1x2xAWG22 + 1x2xAWG24 – Total braid shield - PUR jacket - AWM Style 20236 (80°C / 30V)
CODE : 86AVST1401-013
Homologation UL AWM style: 20236
Accordance to Directives: 2011/65/CE; 2015/863/UE
Accordance to Directives: The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012.
GENERAL CONSTRUCTION
Data pair 1x2xAWG24
Conductor:Stranded tin copper wire 0.10mm; nom. 0.25mm² - AWG24; nominal diameter 0.62mm; Cl.6 VDE0295.
Lay agree with UL 758 tab 5.9; conform to EN 13602 - ETP1, DIN 40500 E-Cu 58.
Insulation: Foam Polyolefin; nominal diameter 2mm; Colour cores: White – Blue.
Assembly:Two cores twisted together.
Shield: Al/PET; Aluminium foil outside; Optical coverage 100%
Power pair 1x2xAWG22
Conductor:Stranded tin copper wire 0.10mm; nom. 0.34mm² - AWG22; nominal diameter 0.8mm; Cl.6 VDE0295.
Lay agree with UL 758 tab 5.9; conform to EN 13602 - ETP1, DIN 40500 E-Cu 58.
Insulation:Polyolefin; nominal diameter 1.6mm; Colour cores: Red – Black.
Assembly:Two cores twisted together.
Shield:Al/PET; Aluminium foil outside; Optical coverage 100%
Assembly
1x2xAWG22 + 1x2xAWG24 stranded together around a central drain wire.
DW: Stranded tin copper wire; nom. 0.34mm² - AWG22.
Shield
Braid type; Tin copper wire; Nominal optical coverage 85%.
Protective tape:
Tape over shield.
Jacket:
PUR (ether base); 90 ShA; Diameter 7.2 ±0.25mm; colour Violet similar RAL4001. conform to UL AWM Style 20236.
TECHNICAL DATA
Electric
Operating voltage 300 Vrms
Voltage test 700 Vac
Peak Operating Voltage 125Vdc (not for high voltage purposes)
Cable suitable for installation in coexistence with Category I energy cables with voltage rating up to 0,6/1 KV according to CEI-UNEL 36762.
Physical
Operating temperature range -40°C to +80°C (fixed)
Operating temperature range -20°C to +80°C (flex, free movement not continuous)
Minimum bending radius 5 x D (fixed)
Minimum bending radius 10 x D (flex, free movement not continuous)
Chemical
Oil resistant - yes (UL758)
Silicone, Pb, Cd, Hg, FCKW free - yes
Halogen free - yes (CEI EN 60754-1 / VDE 0482-754-1)
Electrical transmission properties @20°C:
Operating voltage - 30 Vrms
Voltage test C/C - 2000 Vac
Voltage test C/S- 1000 Vac
Max conductor resistance AWG24 - 89.8 Ω/Km (IEC60344)
Max conductor resistance AWG22 - 68.4 Ω/Km (IEC60344)
Characteristic Impedance - 120 Ω ±15%
Transfer impedance - Grade 2 according to IEC61156-6:2020 §6.2.7
Capacitance @ 1KHz - 46 pF/m (nominal)
Attenuation @ 1MHz - 2.3 dB/100m
Attenuation @ 500KHz - 1.64 dB/100m
Attenuation @ 125KHz - 0.95 dB/100m
Insulation resistance >5.0 GxKm
Flame
Flame resistant - UL Cable flame test; IEC 60332-1-2
Cavi BUS e DATI questa tipologia di cavi viene utilizzata per gestire la trasmissione dati per sistemi complessi dove si richiedono valori di impedenza e velocità di trasmissione. Sono disponibili due gamme di prodotti per posa dinamica o posa statica, in rispondenza alle omologazioni UL, CSA e DESINA.