Single Pair Ethernet - Sect. 2xAWG26/7 – Tape & Braid Shielded - PUR jacket AWM Style 20554 (80°C/30V)
CODE: 86A26SS2C7-004
Homologation UL AWM style: 20554
Accordance to Directives: 2011/65/CE; 2015/863/UE
Accordance to Directives:
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012.
GENERAL CONSTRUCTION
Conductor
Stranded bare copper wire 7x0.16mm (nom. 0.14mm²- AWG26); nominal diameter 0.48mm.
Lay agree with UL 758 tab 5.9; conform to EN 13602 - ETP1, DIN 40500 E-Cu 58.
Insulation
Foam PE compound; nominal diameter 1.03mm; Colour cores: Blue - White polarized Blue.
Assembly
Two cores twisted in a pair with fillers in gap.
Protective tape
Optional tape over assembly.
Jacket
PUR compound; diameter 4.5 ±0.2mm; colour Green similar RAL6018; conform to UL AWM Style 20554.
TECHNICAL DATA
Electric
Operating voltage 300 Vrms (UL 30 V)
Voltage test 500 Vac
Max conductor resistance
150.3 Ω/Km (IEC60344)
Impedance
100 Ω ±15%
Cable suitable for installation in coexistence with Category I energy cables with
voltage rating up to 0,6/1 KV according to CEI-UNEL 36762.
Physical
Operating temperature range -40°C to +80°C (fixed)
Operating temperature range -25°C to +80°C (flex)
Minimum bending radius 5 x D (fixed)
Minimum bending radius 12.5 x D (flex)
UV resistant yes (UL1581 Standard requirement on complete cable)
Chemical
Oil resistant yes (UL758)
Silicone, Pb, Cd, Hg, FCKW free yes
Halogen free yes (CEI EN 60754-1 / VDE 0482-754-1)
Flame
UL Horizontal flame test; CSA FT2; IEC 60332-1-2
Accordance to:
IEC 61156-12
BUS and DATA cables this type of cable is used to manage data transmission for complex systems where impedance values and transmission speed are required. Two product ranges are available for dynamic installation or static installation, compliant with UL, CSA and DESINA approvals.