• November 24, 2024
  • Via Mappano 30/G-H 10071 Borgaro Torinese

CAN OPEN

CABLE Li02Y(St)C11Y CanBUS - sect. 2x2x0.34mm² - Braid Shield – PUR jacket O.D. 6.70mm - AWM Style 20236 (80°C / 30V)

CODE : 86A22T1401-E30

Homologation UL AWM style: 20236

Accordance to Directives: 2014/35/UE; 2014/30/UE;                                         2011/65/CE; 2015/863/UE

                                       CAN BUS Accordance to: ISO 11898-2

GENERAL CONSTRUCTION

2x2x0.34mm²
Conductor

Stranded Bare copper wire; 42x0.10mm (nom. 0.34mm² - AWG22); nominal diameter 0.80mm; cl.6 VDE0295;
Lay agree with UL 758 tab 5.9; Conform to EN 13602 - ETP1, DIN 40500 E-Cu 58.

Insulation

Foam PE (with internal and external skin); hardness 61 ShD; diameter 1.75 ±0.10mm; Colours cores: White-Brown-Green-Yellow as for DIN47100.

Assembly

Four cores stranded in star quad (see indicative sketch); some filler could be used for a better roundness.

Shield

First: Al/PET tape wrapped over total assembly (Aluminium face outside); Optical coverage 100%.
Second: Braid type; Tin copper wire 0.10mm; nominal optical coverage 80%.
Drain wire: Stranded Tin copper wire 0.25mm² (AWG24); DW under braid shield.

Protective tape:

PET tape wrapped over assembly.

Protective tape:

Nonwovens tape (TNT) over total shield.

Jacket:

PUR, hardness 92 ShA; diameter 6.70 ±0.20mm; colour Violet similar RAL4001; conform to UL 20236.

TECHNICAL DATA

Electrical

Operating voltage 30V
Voltage test 1000 V x 1min
Max conductor resistance 61.6 Ω/Km
Impedance 120 Ω ± 10%
Nominal Capacitance @1KHz: 50 pF/m

Chemical

Oil resistance yes (UL758; ISO6722)
Free of FCKW, Silicone and Pb - yes
Halogen free - yes (CEI EN 60754-1 / VDE 0482-754-1)

Physical

UV resistant yes (UL1581– 300h)
Max installation pulling force 50N

Physical

Operating temperature range -40°C to +80°C (fixed)
Operating temperature range -30°C to +80°C (free motion without periodic recurrence and forced guidance)
Bending radius >10 x OD (fixed)
Bending radius >15 x OD (Flex and drag chain)
UV resistant yes (UL1581/2556– 300h)

Flame

Flame resistant
UL Cable Flame test; CSA FT1; IEC 60332-1; ISO6722

Movement data @20°C:

Acceleration: up to 20 m/sec²
Speed: up to 300 m/min
Torsion: ±30° (Optimal recommended)

Default criterium of the norm-bendings is electrical failure due to conductor breakage or conductor short-circuit. Extreme sheath adhesion is not a default criterium since it cannot be influenced by the cable manufacturer (e.g. through big abrasion between cable and chain, non-suitable chain construction or wrong installation of cable in the chain).

BUS and DATA cables this type of cable is used to manage data transmission for complex systems where impedance values and transmission speed are required. Two ranges of products are available for dynamic installation or static installation, in compliance with UL, CSA and DESINA approvals.

Do you want to receive the technical specifications?

Fill out the form below

Contact Form inglese specifiche tecniche