• November 24, 2024
  • Via Mappano 30/G-H 10071 Borgaro Torinese

OCS BOSCH® – HP

Hybrid Servo cable according to
BOSCH® INDRAMAT ACURO – PUR

certificazioni cavi movinflex-2

CONSTRUCTION

Conductor

Flexible bare copper conductor Cl.6
According to IEC60228 / VDE0295

Insulation

Polyolefin compound

Color Cores

Power: Yellow/Green + Black printed 1 to 3
Pair: Black printed 7 and 8

Shield

Pair: Tinned copper braid
Nominal optical coverage 85%
Total: Tinned copper braid
Nominal optical coverage 85%

Protective Tape

Pair: Tape under and over shield
Total cable: Tape under and over shield
- Ethernet Cat.5e
Flexible bare copper conductor
Insulation
Polyolefin compound
Shield
Al/PET tape under shield
Tinned copper braid
Nominal optical coverage 90%
Protective Tape
Tape over assembly and over braid shield
Jacket
Polyolefin compound Black similar RAL9005

Jacket

PUR (ether base),
Compound accordance to UL758
Color Jacket: Orange similar RAL2003

Packaging

Wood drums or Plywood spools

TECHNICAL DATA

Nominal Voltage

1000 Vrms

Test Voltage

3000 Vac

Temperature

-40°C to +80°C (Fixed)
-30°C to +80°C (Flexible)

Bending Radius

5 x D (Fixed)

Electrical properties Cat.5e @20°C:

Voltage test C/C 1500 Vac
Characteristic Impedance 100Ω ±15Ω
Capacitance @1KHz 55 pF/m ±15 pF/m
Capacitance (C/S) 105 pF/m ±15 pF/m
Nominal Inductance 0.5 μH/m

Movement Data @20°C

Bending cycles*: up to 5Mio (10 Mio Stroke)
Minimum bending radius*: 10 x D
Max speed*: 300 m/min
Max acceleration*: 50 m/sec²

*The given values have been tested individually

RESISTANCE

Flame Resistance

UL Cable flame test
CSA FT1
IEC60332-1-2

Oil Resistance

According to UL758

Approval

Halogen free according to
CEI EN 60754-1 / VDE 0482-754-1
UV Resistance
Silicone, Pb, Cd, Hg, FCKW free
RoHS compliant
2014/35/UE; 2014/30/UE; 2011/65/CE; 2015/863/UE
UKCA compliant Electrical Equipment (Safety) Regulations 2016 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012.

TECHNICAL DATA

CABLE CONSTRUCTION

CODICE JACKET ULAWM STYLE N° CORES x CROSS SECTION (mm²)
Power + Pair + Ethernet Cat.5e
OUTER DIAMETER (mm)
MOV-4G15ACURO-PU PUR 21223 (4x1,5 + 1x(2x0,75) + (4x0,2)) 13
MOV-4G25ACURO-PU PUR 21223 (4x2,5 + 1x(2x1,0) + (4x0,2)) 14.6
MOV-4G075ACUR1-PU PUR 21223 (4x0,75 + 1x(2x0,75) + (4x0,34)) 13.3
MOV-4G15ACUR1-PU PUR 21223 (4x1,5 + 1x(2x0,75) + (4x0,34)) 13.4
MOV-4G25ACUR1-PU PUR 21223 (4x2,5 + 1x(2x1,0) + (4x0,34)) 15
MOV-4G100ACUR1-PU PUR 21223 (4x10 + 1x(2x1,5) + (4x0,34)) 22

This type of cable is used in the automation sector to send all the information from PLC, CNC to peripherals. It is possible to choose the appropriate type of cable based on the user’s needs, with PUR sheath for critical environmental conditions or higher handling speed, with PVC sheath for less critical environmental conditions or lower handling speed, based on approvals UL, CSA and DESINA. The Movinflex technical staff works with the utmost professionalism and precision to guarantee the customer a high-performance and long-lasting product. The company has always collaborated with the best manufacturers which allow it to offer the best products at highly competitive prices.

Do you want to receive the technical specifications?

Fill out the form below

Contact Form inglese specifiche tecniche