Pwer over Ethernet Cat7 – Dynamic use

Industrial Ethernet Cable Cat.7 – Sect. 4x(2xAWG26/7) -
PUR jacket O.D. 6.90mm - AWM Style 20236 (80°C / 30V)

CODE: 86A26SS8C7-004

UL AWM style: 20236 (80°C/30V)

Accordance to Directives: 2011/65/CE; 2015/863/UE

Accordance to Directives: The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012.

GENERAL CONSTRUCTION

Conductor

Stranded bare copper wire 7x0.16mm (nom. section 0.14mm²- AWG26); nominal diameter 0.48mm.
Lay agree with UL 758 tab 5.9; conform to EN 13602 - ETP1, DIN 40500 E-Cu 58.

Insulation

PEE compound (02Y); nominal diameter 1.03mm; colours Orange - White polarized Orange - Green –
White polarized Green – Brown - White polarized Brown - Blue - White polarized Blue

Pairs assembly

Cores twisted in pairs; Pairs colours (Orange - White pol. Orange) - (Green - White pol. Green) - (Brown - White pol. Brown) - (Blue - White pol. Blue).

Pairs shield

Each pair shielded with Al/PET tape (Aluminium face outside); optical coverage 100%.

Total assembly

Braid type; Tin copper wire; nom. optical Coverage 75%.

Total shield

Braid type; Tin copper wire; nominal optical Coverage 80%.

Jacket

PUR compound (11Y); diameter 6.9 ±0.2 mm; colour Green similar RAL6026.

Package

Plywood spool d. 800mm

TECHNICAL DATA

Electric

Operating voltage 50 Vrms (UL 30V)
Voltage test 500 Vac

Physical

Operating temperature range -40°C to +80°C (fixed)
Operating temperature range -25°C to +80°C (flex)
Minimum bending radius 7.5 x D (fixed) UV resistant - yes (UL1581)

Chemical

Oil resistance - yes (UL758;
Silicone, Pb, Cd, Hg, FCKW free - yes
Halogen free - yes (CEI EN 60754-1 / VDE 0482-754-1)

Movement data @20°C:

Minimum bending radius* 10 x D
Bending cycles* 4 Mio (8 Mio Stroke)
Max speed* 300 m/min
Max Acceleration* 50 m/sec²
Torsion*: ± 90°/m (5 Mio cycles)

Electrical transmission properties @20°C:

Max electric resistance 150.3 Ω/Km (IEC 60344)
Nominal Impedance 100 Ω
Capacitance @1KHz 47 pF/m (nominal)
Propagation velocity 80 % (nominal)
Propagation delay <534 ns/100m
Delay skew <45 ns/100m
Transfer Impedance 5 mΩ/m @10MHz
Channel Class D (Cat5e – 100MHz) max 72m (0.8 dB loss for RJ45 connectors)
Channel Class E (Cat6 – 250MHz) max 67m (0.8 dB loss for RJ45 connectors)
Channel Class EA (Cat6A – 500MHz) max 67m (0.8 dB loss for RJ45 connectors)
Channel Class F (Cat7 – 600MHz) max 67m (0.8 dB loss for TERA connectors)

Flame

UL Cable flame test; UL VW-1; CSA FT1; IEC 60332-1-2

Accordance to:

IEC 61156-6 - Work area wiring Cat.7
ISO11801-1 §9.3.2.6 - Flexible cable Class F
Suitable for Fast Connect technology

Cavi BUS e DATI questa tipologia di cavi viene utilizzata per gestire la trasmissione dati per sistemi complessi dove si richiedono valori di impedenza e velocità di trasmissione. Sono disponibili due gamme di prodotti per posa dinamica o posa statica, in rispondenza alle omologazioni UL, CSA e DESINA. 

Desideri ricevere le specifiche tecniche?

Compila il form qui sotto

Contatti Form italiano specifiche tecniche (#7)