• Novembre 24, 2024
  • Via Mappano 30/G-H 10071 Borgaro Torinese

PROFINET TYPE C

Network cable ProfiNET Type C - 2x2xAWG22 - inner jacket - Shield - PUR jacket O.D. 6.80mm

CODE : 86A22SS40D-004

Homologation UL AWM style: 20233

Accordance to Directives: 2014/35/UE; 2014/30/UE;                                         2011/65/CE; 2015/863/UE

GENERAL CONSTRUCTION

Conductor

Tinned copper strand; according to EN 13602 - ETP1; stranding according to DIN VDE 0295, EN60228 Class 6 Stranded lay compliant with UL 758.

Wire structure:

Nominal section
(mm²)
AWG Stranding
(nbr of wires x wire diameter in mm)
Diameter of stranded core
(mm)
Max Resistance
Ref. std. IEC 60344
(Ω/km)
0.34 22 19x0.15 0.75 64.2

Insulation

Thermoplastic PE; Max Insulation resistance >200 MΩxkm (IEC60189-1&IEC60885-1 or EN50289-1-4); nominal hardness 61 Shore D; according to UL758, cores colors Yellow-Blue-Orange-White.

Insulation diameter

Nominal section
(mm²)
Nominal Ø
(mm)
Nominal thickness
(mm)
0.34 1.45 19x0.15

Assembly

Cores stranded together (central filler could be used)

Inner jacket

Flame retardant compound. Nominal diameter 4.30mm, colors natural.

Duble Shield

Tape: Al/PET tape (Aluminum face outside), nominal optical coverage 100%.
Braid: Tin copper wire, nominal optical coverage 80%.

Tape:

PET tape over braid shield.

Jacket:

Polyurethane (PUR, TPU), ether base, Halogen free, nominal hardness 92 Shore A; Silicone, Pb,Cd,Hg & FCKW free; according to UL758. Diameter 6.80 ±0.20mm, colour Green similar RAL6018

*The given values have been tested individually

TECHNICAL DATA

Electrical

Voltage rating 300 V
Voltage test on core 1500 Vrms x 1 min. (EN50395)

Temperature

Temperature range (fixed) -40°C to +80°C
Temperature range (flex) -20°C to +70°C (free motion without periodic recurrence and forced guidance)

Chemical

Oil resistance yes (UL758)
Free of FCKW, Silicone and Pb yes
Halogen free yes (CEI EN 60754-1 / VDE 0482-754-1)

Physical

UV resistant yes (UL1581– 300h)
Max installation pulling force 50N

Movement data @20°C:

Minimum bending radius* 7.5 x D (up to 3 Mio Bending cycles / 6 Mio Stroke) Minimum
Minimum bending radius* 12.5 x D (up to 10 Mio Bending cycles / 20 Mio Stroke) Minimum
Max speed* 300 m/min
Max acceleration* 50 m/sec²
Torsion ± 30°/m (Max cycles 2Mio)

Flame

UL Cable Flame Test pass
UL VW-1, CSA FT1 pass
IEC 60332-1 pass
IEC 60332-2 pass

Compliance

Accordance to:
▪ 2014/35/UE; 2014/30/UE; 2011/65/CE (RoHS)
▪ ProfiNET cabling and interconnection technology Guideline for ProfiNET (3.1 March 2014)
▪ Cat.5e flex patch cord ▪ UL/CSA (UL AWM Style 20233, use: external interconnect. of electronic equipment)

Cavi BUS e DATI questa tipologia di cavi viene utilizzata per gestire la trasmissione dati per sistemi complessi dove si richiedono valori di impedenza e velocità di trasmissione. Sono disponibili due gamme di prodotti per posa dinamica o posa statica, in rispondenza alle omologazioni UL, CSA e DESINA. 

Desideri ricevere le specifiche tecniche?

Compila il form qui sotto

Contatti Form italiano specifiche tecniche (#7)